Marathon Electric Pancake Spécifications Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
5
f. If residual voltage is normal, the capacitor is defective
and should be replaced.
Checking Diodes
a. Check each diode individually by removing the (+) rotor
lead stud connection (see Figures 2 and 3). Diodes are
good if the resistance reading is approximately mid-
scale on the lowest ohm rating.
b. Check for leakage in each diode by reversing their
polarity. Diodes are good if the resistance reading is
infinite. A faulty diode will give a resistance value of zero.
c. Prior to installing a replacement diode, clean the surface
of the exciter rotor core, and run a bead of a thermal-
electrical compound around the base of the diode. The
diode threads should not be coated.
d. Torque the diode base to 20–30 in-lb. Do not over
torque the diode base
.
Ordering Parts
When ordering parts, always include the name and quantity
of each part along with the serial and model numbers from
the generator nameplate.
For parts ordering information, contact:
Marathon Electric Manufacturing Corporation
100 E. Randolph St.
P.O. Box 8003
Wausau, WI 54402-8003
Phone: 715.675.8257
or: 800.477.6362, ext. 8257
RETURNED GOODS
Consult Marathon Electric Manufacturing Corporation for
authorization before returning any product. We cannot be
responsible for any items returned without authorization.
CAUTION: Single bearing generators must have their
rotor assembly properly secured to prevent damage
during transit to the factory, or to an authorized service
center.
Checking the Capacitor Charge
a. Check the capacitor “charge and discharge” readings
using an ohmmeter on the RX-1000 scale.
b. Place the ohmmeter leads on the capacitor terminals
one at a time. A meter deflection should be seen
(charging), followed by a slow return to infinity
(discharging).
c. Reverse the ohmmeter leads and repeat the procedure.
The results should be the same. No meter deflection or
continuity indicates a defective capacitor. Replace the
device.
Figure 2
Figure 3
Vue de la page 4
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire